CLT and Mass Timber Acoustics Statistics (2026): 55+ Data Points on Bare Panel Ratings, Flanking Transmission, and Occupant Noise Satisfaction

CLT and mass timber acoustics statistics 2026: bare 5-ply CLT floors test at IIC 25 against a code target of 50, plus flanking, toppings and 2,833 U.S. projects.

A bare 5-ply cross-laminated timber floor rates just IIC 25, half the IIC 50 the International Building Code requires between apartments (WoodWorks, Acoustics and Mass Timber 2021). Airborne performance is closer but still short: a 175 mm CLT panel measured STC 41 and STC 42 in two NRC Canada lab tests three years apart (NRC Client Report A1-006070.10, 2015). Meanwhile the building type is spreading quickly, with 2,833 U.S. mass timber projects built or in progress as of June 2026 (WoodWorks Mapping Mass Timber 2026). Most of the acoustic work in these buildings happens at the junctions, where flanking transmission decides whether a good lab assembly becomes a good apartment, a problem shared with the low-frequency structure-borne paths covered in our subwoofer and HVAC noise transmission statistics. We aggregated data from WoodWorks, the National Research Council Canada, SINTEF, Luleå University of Technology, the University of Bologna, Japan’s National Institute for Land and Infrastructure Management, and a dozen more journal and conference sources.

TL;DR

  • 2,833 U.S. multifamily, commercial or institutional mass timber projects were built or in progress as of June 2026 (WoodWorks Mapping Mass Timber 2026).
  • A bare 5-ply CLT floor rates STC 41 and IIC 25, against code minimums of STC 50 and IIC 50 (WoodWorks, Acoustics and Mass Timber 2021).
  • A bare 160 mm CLT slab tested at Ln,w 84 dB, and engineered overstructures cut that by up to 28 dB (Luison et al., Forum Acusticum 2026).
  • Asymmetric fixings at CLT junctions can add up to 10 dB of lateral transmission versus theoretical values (Di Bella and Mitrovic, Sustainability 2020).
  • Decoupling a CLT floor slab with a resilient interlayer raised the low-frequency vibration reduction index by 11.3 dB (Barbaresi et al., Forum Acusticum 2026).
  • Wall-to-wall junction attenuation drops about 1.0 dB per storey at X-junctions and 1.6 dB at T-junctions lower in CLT buildings (Nilsson et al., Buildings 2023).
  • Field R’w of double CLT walls landed within -2 to +1 dB of comparable lab results (Homb and Conta, SINTEF, Forum Acusticum 2023).
  • The standard impact rating explained only 18% of residents’ footstep annoyance across 23 Swedish buildings, versus 77% when measured from 25 Hz (Ljunggren et al., Applied Acoustics 2017).
  • 25.3% of Japanese residents in wooden apartment buildings were very dissatisfied with sound insulation, against 13.0% in reinforced concrete (NILIM Annual Report 2023, MLIT 2018 survey data).

1. The Mass Timber Pipeline: How Many Buildings Need Acoustic Answers

The project count matters for acoustics because almost every multifamily mass timber building needs a tested floor-ceiling and wall detail. WoodWorks counted 2,833 U.S. multifamily, commercial or institutional mass timber projects built or in progress as of June 2026, a figure it updates quarterly on its Mapping Mass Timber page. WoodWorks notes that “details on in-design projects are not publicly available,” so that count leaves out the design pipeline.

Growth is steady rather than explosive. A Mercer Mass Timber analysis reported by IWF Atlanta describes a 20 percent annual growth rate in place since 2015, and the same article cites the 2024 International Mass Timber Report for annual building counts. More buildings means more repeat details, and repeat details are where tested acoustic assemblies pay off.

MetricValueSource
U.S. mass timber projects built or in progress (June 2026)2,833WoodWorks Mapping Mass Timber 2026
U.S. mass timber projects built, under construction or in design (2026)2,746WoodWorks via Woodworking Network, June 24, 2026
U.S. projects built or in progress at end of 2025Over 2,500Mercer Mass Timber analysis via IWF Atlanta
Annual growth rate in project count since 201520 percentMercer Mass Timber analysis via IWF Atlanta
Mass timber buildings constructed per year, Canada and U.S.151 (2019) to 279 (2023)2024 International Mass Timber Report via IWF Atlanta
Mass timber production, Canada and U.S.158,000 m3 (2019) to 393,000 m3 (2023)2024 International Mass Timber Report via IWF Atlanta

Context note: the 2,746 figure reported by Woodworking Network is described as including design-phase projects, yet it is lower than WoodWorks’ own 2,833 built-or-in-progress count. Neither source explains the gap; see the Data watch note.

2. Bare Panels: What CLT Delivers Before Any Treatment

Bare CLT is heavy for wood but light for a floor slab. WoodWorks compares a roughly 7 inch CLT panel at about 18 psf and STC 41 with a 6 inch concrete slab at about 80 psf and STC 53, which explains the whole acoustic problem in one line: mass drives sound insulation, and the CLT panel carries about 23% of the slab’s weight (18 psf divided by 80 psf). Its Acoustics and Mass Timber solution paper states that bare mass timber panels rarely provide adequate noise control on their own.

Impact noise is the larger gap. A bare 5-ply floor rates IIC 25 and a 7-ply floor IIC 30, while code asks for IIC 50. European lab data shows the same picture in ISO terms: a bare 160 mm CLT slab measured Ln,w 84 dB and Rw 35 dB in a 2026 University of Bologna and Isolgomma campaign (Luison et al., Forum Acusticum 2026).

MetricValueSource
Bare 5-ply CLT floor, 6.875 in.STC 41, IIC 25WoodWorks, Acoustics and Mass Timber 2021
Bare 7-ply CLT floorSTC 44, IIC 30WoodWorks, Acoustics and Mass Timber 2021
Bare 175 mm 5-ply CLT (91 kg/m2), lab tests in 2012 and 2015Floor STC 41 and 42, wall STC 39 and 37NRC Client Report A1-006070.10, 2015
Bare 131 mm CLT floorSTC 39NRC Client Report A1-006070.10, 2015
Bare 160 mm CLT floor (ISO lab)Ln,w 84 dB, Rw 35 dBLuison et al., Forum Acusticum 2026
Bare CLT floors, normalized impact level by thicknessLn,w 81-87 dBDi Bella and Mitrovic, Sustainability 2020
Bare CLT wall vs standardized lightweight wall of similar mass (about 70 kg/m2)Rw 37 dB vs 33 dBDi Bella and Mitrovic, Sustainability 2020

Outlier note: a 120 mm CLT wall tested in Taiwan reached Rw 45 and STC 45 without added layers (Lin et al., Materials 2021), well above the Rw 32-33 dB that SINTEF compiled for 78-100 mm single CLT walls tested in Canadian, Austrian and Norwegian labs (Homb and Conta, Forum Acusticum 2023). NRC’s repeat testing also warns of a variation of about plus or minus 2 STC points when bare CLT assemblies are rebuilt. Most recent available data for the NRC series: NRC Canada, 2015.

3. Code Targets and What Occupants Actually Hear

Code minimums describe a legal floor, not comfort. The ICC benchmark for multifamily housing is STC 50 and IIC 50 in the lab, relaxed to 45 for field tests, as summarized in the University of Oregon’s 2019 TallWood acoustic lab testing report on CLT and mass plywood panels. Canada moved further toward field reality in 2015 by letting designers show either ASTC 47 or a lab STC 50, according to a 2024 review of the National Building Code in Construction Canada.

FPInnovations’ perception thresholds explain why consultants push past code. Below a field rating of 45 neighbours are clearly audible, and only above 60 do occupants hear nothing except low-frequency footsteps on lightweight floors. A bare CLT floor at IIC 25 sits 20 points under even the lowest of those bands (45 minus 25), although that compares a lab rating with a field threshold.

MetricValueSource
IBC requirement, lab (STC and IIC)50University of Oregon TallWood acoustic report 2019, citing ICC
IBC requirement, field tested45University of Oregon TallWood acoustic report 2019, citing ICC
Canada NBC 2015 option for dwelling separationsASTC 47 or lab STC 50Construction Canada, Busch 2024
Canada NBC: year STC 50 between dwellings was adopted1990Construction Canada, Busch 2024
Field rating below which neighbour sounds are clearly audibleUnder 45FPInnovations Report E-4874, 2014
Field rating at which sound is heard as muffledAbove 50FPInnovations Report E-4874, 2014

Context note: Construction Canada reports that the next NBC edition was expected in 2025 with impact insulation (IIC) under consideration, since the 1995 code referenced IIC without requiring design or testing for it. Most recent available data for the FPInnovations thresholds: FPInnovations, 2014.

4. Toppings, Floating Floors and Ceilings: Closing the Gap

Every route to code adds layers, and the numbers show which layers do the work. A hung ceiling combined with a topping took 175 mm CLT floors to STC 62-75 in NRC Canada’s lab, across a test program of 16 floor assemblies on a 175 mm base, 10 on a 131 mm base and 8 walls (NRC Client Report A1-006070.10, 2015). A heavy topping of 100+ kg/m2 on a resilient membrane alone yields at least STC 50.

Impact performance responds most to the floating layer and the ceiling. In the 2026 Bologna campaign, a dry floating screed brought Ln,w down to 46-53 dB, and adding a suspended ceiling pushed it to 36-40 dB. The architectural tension is real: the authors note suspended ceilings are “most of the times not accepted by designers” who want the timber exposed. Testing the full assembly before specifying it is the same discipline described in our anechoic chamber and acoustic testing statistics.

MetricValueSource
5-ply CLT floor with topping and acoustic mat, before finish floorSTC 50-59, IIC 35-60WoodWorks, Acoustics and Mass Timber 2021
Same assemblies with finish flooringIIC 60+WoodWorks, Acoustics and Mass Timber 2021
175 mm CLT floors with hung ceiling and toppingSTC 62-75NRC Client Report A1-006070.10, 2015
CLT walls with gypsum liningsSTC 53 or higher (best: STC 71)NRC Client Report A1-006070.10, 2015
Reduction in Ln,w from engineered overstructures on 160 mm CLTUp to 28 dB (Rw up to +25 dB)Luison et al., Forum Acusticum 2026
CLT plus suspended ceiling and floating screedLn,w 36-40 dBLuison et al., Forum Acusticum 2026
Impact improvement of the same floating floor on CLT vs concreteDelta Lw 31 dB vs 34 dBLuison et al., Forum Acusticum 2026
CLT walls with single-sided vs double-sided liningsUp to 60 dB vs up to 70 dBDi Bella and Mitrovic, Sustainability 2020

Outlier note: the Bologna team found a timber-batten overstructure with polyester fibre infill at about 16 kg/m2 performed close to sand or cement layers at 90-100 kg/m2, which matters because every kilogram of topping adds structural load to a timber frame. The same paper notes that once low frequencies are counted (LI,50), dry and wet screed systems converge at 54-55 dB. Engineered absorbers inside these assemblies follow the same physics as those in our acoustic metamaterials and soundproofing statistics.

5. Flanking Transmission at Junctions: Where Lab Ratings Leak

Flanking is the reason a good separating floor can still fail in the field. CLT is stiff and radiates efficiently, so vibration crosses junctions and re-radiates from the floor or wall next door. In a 2026 University of Bologna full-scale X-junction mock-up, splitting a continuous 100 mm CLT floor slab and adding a resilient interlayer raised the low-frequency vibration reduction index from 9.6 dB to 20.9 dB, an 11.3 dB gain (Barbaresi et al., Forum Acusticum 2026).

The ISO 12354 calculation in the same paper puts that into apartment terms. Without a false ceiling, decoupling lifted the apparent sound reduction index R’w from 46.5 dB to 49.3 dB; with a ceiling the gain shrank to 0.8 dB because the ceiling already makes the major contribution on the ceiling-to-ceiling path. Building height compounds the problem: across four CLT buildings of 5 to 10 storeys, junctions lower in the building attenuated less (Nilsson et al., Buildings 2023).

MetricValueSource
Average Kij, continuous vs decoupled CLT floor (200-1250 Hz)10.7 dB vs 17.6 dB (+6.9 dB)Barbaresi et al., Forum Acusticum 2026
R’w gain from floor decoupling, no false ceiling (ISO 12354 calc)+2.8 dB (46.5 to 49.3 dB)Barbaresi et al., Forum Acusticum 2026
Ceiling-to-ceiling (Ff) flanking path improvement from interlayer+5.8 dBBarbaresi et al., Forum Acusticum 2026
Wall-wall Kij decrease per storey lower in the building1.0 dB (X-junctions), 1.6 dB (T-junctions)Nilsson et al., Buildings 2023
Junctions measured in that field study12 junctions, 36 flanking paths, 4 buildingsNilsson et al., Buildings 2023
Extra lateral transmission from asymmetric fixingsUp to 10 dB vs theoretical valuesDi Bella and Mitrovic, Sustainability 2020
Prediction error of a wave-based model for a CLT T-junction with interlayerBelow 10 dB in all 1/3-octave bandsMoons, Reynders and Lanoye, INCE conference proceedings 2024
Extra vibration reduction from a 12 mm elastomer layer inside CLT panels (simulated)About 40%Bohman et al., Journal of Building Engineering 2025

Context note: the Bologna paper is a preliminary conference document co-authored with a fastener and acoustic-strip manufacturer (Rotho Blaas), and its R’w figures come from a calculation rather than a built apartment. Field evidence points the same way: a 2026 measurement study of three mass timber schools in the Pacific Northwest found flanking “strongly affects” both ASTC and AIIC results (Blount, JASA 2026). On the materials side, swapping spruce laminations for birch or compressed spruce cut simulated vibration response by about 30% and 50% (Bohman et al., 2025).

6. Field vs Lab: How Much Performance Survives Construction

The gap between lab and field is smaller than many designers fear, but only when workmanship cooperates. SINTEF’s comparison of double CLT walls found field R’w deviated from comparable lab results by only -2 to +1 dB (Homb and Conta, Forum Acusticum 2023). The same study shows how easily it goes wrong on site: compressed blown-in cavity insulation cost 9 dB of R’w compared with a soft installation in the same apartment building.

North American guidance builds in the expectation of loss. Canadian code commentary states an ASTC “will always yield a value equal to or lower than the STC” for the same configuration, because the field-type rating adds every flanking path to the direct one. FPInnovations’ field program found bare 175 mm CLT floors struggled to exceed a rating of 50 without a dropped ceiling (FPInnovations Report E-4874).

MetricValueSource
Field vs lab deviation, double CLT walls (R’w vs Rw)-2 to +1 dBHomb and Conta, SINTEF, Forum Acusticum 2023
Field R’w of double CLT walls, three apartment buildings50-55 dBHomb and Conta, SINTEF, Forum Acusticum 2023
Lab Rw of comparable double CLT walls47-54 dBHomb and Conta, SINTEF, Forum Acusticum 2023
R’w penalty from compressed blown-in cavity insulation (field)9 dBHomb and Conta, SINTEF, Forum Acusticum 2023
ASTC compared with STC for the same configurationAlways equal or lowerConstruction Canada, Busch 2024
Bare 175 mm CLT floors without a dropped ceiling, field ratingsStruggled to exceed 50FPInnovations Report E-4874, 2014
Mass timber schools measured in situ, Pacific Northwest3 schools; exposed CLT ceilings can meet a 0.6 s reverberation target if walls are treated (preliminary)Blount, JASA 2026

Context note: the SINTEF authors conclude that, in general, R’w of 55 dB or more is not achievable for these double CLT walls without additional measures, which they describe as the common requirement between apartments. That makes the target a design problem, not just a construction-quality one.

7. Occupant Noise Satisfaction: The Low-Frequency Problem

Residents judge timber buildings by footsteps, and the standard ratings miss most of what they hear. Across 23 Swedish apartment buildings, the conventional impact rating L’nT,w explained only 18% of residents’ footstep annoyance; extending the evaluation down to 25 Hz raised that to 77%, and to 85% after removing one outlier building (Ljunggren, Simmons and Öqvist, Applied Acoustics 2017). Six of those 23 buildings were CLT, and roughly 800 completed questionnaires fed the analysis.

The national picture from Japan is blunter. In the 2018 Comprehensive Survey of Housing and Living, 25.3% of residents in wooden apartment buildings said they were very dissatisfied with sound insulation and 41.5% rated it somewhat unsatisfactory, against 13.0% and 37.1% in reinforced concrete (NILIM Annual Report 2023). Adding the two categories gives 66.8% dissatisfied in wooden buildings (25.3 + 41.5) versus 50.1% in concrete (13.0 + 37.1). Low-frequency annoyance is also a factor in shared workplaces, as our open-plan office distraction statistics show.

MetricValueSource
Share of footstep annoyance explained by L’nT,wR2 = 18%Ljunggren et al., Applied Acoustics 2017
Share explained by L’nT,w + CI,50-2500R2 = 49%Ljunggren et al., Applied Acoustics 2017
Share explained when evaluated from 25 HzR2 = 77% (85% excluding one outlier)Ljunggren et al., Applied Acoustics 2017
Rating increase from L’nT,w,50 to the 20 Hz AkuLite rating, CLT buildings6.0 dB on average (lightweight 9.2 dB, concrete 0.6 dB)Ljunggren et al., Applied Acoustics 2017
Questionnaire reply rate per building33-83% (about 800 returned)Ljunggren et al., Applied Acoustics 2017
Very dissatisfied with sound insulation, wooden apartments (Japan)25.3% (n=314)NILIM Annual Report 2023, MLIT 2018 survey
Very dissatisfied, reinforced concrete apartments (Japan)13.0% (n=1,125)NILIM Annual Report 2023, MLIT 2018 survey

Context note: the Japanese category covers fireproof and non-fireproof wooden construction as a whole, not CLT specifically, so it describes the perception problem that CLT designers inherit rather than CLT performance itself. Most recent available data: Ljunggren et al., 2017, and MLIT survey data from 2018. The Swedish study also found footstep annoyance at least twice as high as annoyance from other impact sources.

Summary: CLT and Mass Timber Acoustics by the Numbers

MetricValueSource
U.S. mass timber projects built or in progress (June 2026)2,833WoodWorks Mapping Mass Timber 2026
Annual growth rate in project count20 percentMercer Mass Timber analysis via IWF Atlanta
Mass timber buildings constructed per year, Canada and U.S.151 (2019) to 279 (2023)2024 International Mass Timber Report via IWF Atlanta
Bare 5-ply CLT floorSTC 41, IIC 25WoodWorks, Acoustics and Mass Timber 2021
IBC minimum, lab / field50 / 45University of Oregon TallWood acoustic report 2019
Canada NBC dwelling separation optionASTC 47 or STC 50Construction Canada, Busch 2024
Field rating below which neighbour sounds are clearly audibleUnder 45FPInnovations Report E-4874, 2014
Hung ceiling plus topping on 175 mm CLTSTC 62-75NRC Client Report A1-006070.10, 2015
CLT with suspended ceiling and floating screedLn,w 36-40 dBLuison et al., Forum Acusticum 2026
Low-frequency Kij gain from decoupled floor slab+11.3 dBBarbaresi et al., Forum Acusticum 2026
R’w gain from floor decoupling, no false ceiling+2.8 dBBarbaresi et al., Forum Acusticum 2026
Wall-wall Kij loss per storey lower in building1.0-1.6 dBNilsson et al., Buildings 2023
Asymmetric fixings, extra lateral transmissionUp to 10 dBDi Bella and Mitrovic, Sustainability 2020
Field vs lab deviation, double CLT walls-2 to +1 dBHomb and Conta, SINTEF, Forum Acusticum 2023
Extra vibration reduction from a 12 mm elastomer layer in CLT panels (simulated)About 40%Bohman et al., Journal of Building Engineering 2025
Footstep annoyance explained, standard vs 25 Hz rating18% vs 77%Ljunggren et al., Applied Acoustics 2017
Very dissatisfied with sound insulation, wooden vs concrete apartments (Japan)25.3% vs 13.0%NILIM Annual Report 2023, MLIT 2018 survey